BLAKE R - Posts: 23
HELLO,

WHAT SYNTAX WOULD I USE TO NOTE THAT THE BOLLINGER BAND SQUEEZE IS EITHER TRUE OF FALSE [ RED OR YELLOW DOTS ]?

THANK YOU,

BLAKE
[2019-08-23 18:08:45]
Sierra Chart Engineering - Posts: 104368
It would just be if the Bands Ratio subgraph is greater than 0 (true) or less than 0 (false). If you are putting this into an alert, it would look like this to test if it is True:
ID1.SG1 > 0

Where ID1 is the ID number of the Bollinger Squeeze study, and SG1 is the first subgraph of the study, which is the Bands Ratio.

For more information, refer to this section of the Alerts documentation and the section below it:
Study/Chart Alerts And Scanning: Referencing Study Subgraphs