Support Board
Date/Time: Sat, 15 Mar 2025 07:32:27 +0000
Post From: Out of order timestamps although imported scid file correct
[2022-07-11 11:29:59] |
User102394 - Posts: 9 |
Thank you for your prompt reply! I have already checked the scid file and it is correct. However, when I perform manual re-calculation the out-of-order timestamp (as visualized by the out-of-order timestamp study) disappear except for the latest bar. This is an excerpt of the exported bar data: 2022/7/11, 13:17:00, 0.29, 0.29, 0.29, 0.29, 1, 1, 1, 1 2022/7/11, 13:18:00, 0.29, 0.29, 0.29, 0.29, 1, 1, 1, 1 2022/7/11, 13:19:00, 0.29, 0.29, 0.29, 0.29, 1, 1, 1, 1 2022/7/11, 13:20:00, 0.29, 0.29, 0.29, 0.29, 1, 1, 1, 1 2022/7/11, 13:19:00, 0.29, 0.29, 0.29, 0.29, 1, 1, 1, 1 At 13:18, I did a recalculation and the "13:19:00" timestamp will continue repeating from then on. FYI, I have a Intraday Data Storage Time Unit of 10 sec and I use the SC data feed. As I wrote earlier, I did not have the problem earlier. The only thing I changed was the Intraday Data Storage Time Unit (from tick based to 10 sec). Thank you for your help!! Date Time Of Last Edit: 2022-07-11 11:47:17
|