Post From: Out of order timestamps although imported scid file correct

[2022-07-11 11:29:59]
User102394 - Posts: 9
Thank you for your prompt reply!

I have already checked the scid file and it is correct. However, when I perform manual re-calculation the out-of-order timestamp (as visualized by the out-of-order timestamp study) disappear except for the latest bar. This is an excerpt of the exported bar data:

2022/7/11, 13:17:00, 0.29, 0.29, 0.29, 0.29, 1, 1, 1, 1
2022/7/11, 13:18:00, 0.29, 0.29, 0.29, 0.29, 1, 1, 1, 1
2022/7/11, 13:19:00, 0.29, 0.29, 0.29, 0.29, 1, 1, 1, 1
2022/7/11, 13:20:00, 0.29, 0.29, 0.29, 0.29, 1, 1, 1, 1
2022/7/11, 13:19:00, 0.29, 0.29, 0.29, 0.29, 1, 1, 1, 1

At 13:18, I did a recalculation and the "13:19:00" timestamp will continue repeating from then on.

FYI, I have a Intraday Data Storage Time Unit of 10 sec and I use the SC data feed.

As I wrote earlier, I did not have the problem earlier. The only thing I changed was the Intraday Data Storage Time Unit (from tick based to 10 sec).

Thank you for your help!!
Date Time Of Last Edit: 2022-07-11 11:47:17