Login Page - Create Account

Support Board


Date/Time: Fri, 21 Mar 2025 07:54:23 +0000



old versions of studies wont load in new SC versions

View Count: 398

[2022-11-17 23:01:05]
betrading - Posts: 7
Hello,

I have saved .StdyCollct files on to a usb from 2017.

When I drag those files to the data folder on my computer & load them into Sierra Charts & then select them as a Study for my charts... not a single indicator saved.

The name is there but when I look at the Studies Settings... it's completely blank.

Is this because those .StdyCollct Files come from too many years/versions ago?

I use to be able to swap these files from computer to computer without any issues.

Thank You
[2022-11-17 23:15:14]
John - SC Support - Posts: 38835
Yes, the Study Collection is too old.

You can try to recover it by going through the same process as you would for a Chartbook:
Chartbooks (Workspaces): Opening Older Chartbooks

So you would downgrade to version 2204 and see if you can open the Study Collection, and if so, then save it out again under a new name. Then upgrade from 2204 to 2363 and do the same thing. Then upgrade to the current release and you should then be able to use that study collection.
For the most reliable, advanced, and zero cost futures order routing, use the Teton service:
Sierra Chart Teton Futures Order Routing

To post a message in this thread, you need to log in with your Sierra Chart account:

Login

Login Page - Create Account