[Programming Help] - ASCIL - accessing the Setting parameter from an Intraday

View Count: 392

[2021-08-02 21:56:11]
mhren - Posts: 12
I am updating an old trading system based on range bar charts.

Using the sc.GetBarPeriodParameters() function I am able to access the s_BarPeriod::IntradayChartBarPeriodType value to confirm that it is equal to IBPT_RANGE_IN_TICKS_STANDARD. BUT, I cannot see where to get the Intraday Bar Period setting value for this type of chart.

Based on the documentation I would expect this value to be set in s_BarPeriod::IntradayChartBarPeriodParameter1 but this parameter is always 0 even though I have a non-zero value set in the Chart Settings menu.

Where is this setting stored for this type of Intraday chart?