[2020-11-12 18:11:38] |
Walker Zweifel - Posts: 1 |
Reading Internal Order ID file. | 2020-11-12 08:51:38.926 Reading Trade Orders file. | 2020-11-12 08:51:39.000 Reading Trade Positions file. | 2020-11-12 08:51:39.000 Reading Account Balance file. | 2020-11-12 08:51:39.000 UDPListener (1480). Port 22904 | Listening on UDP port 22904. | 2020-11-12 08:51:39.017 Software version: 2182 64-bit | 2020-11-12 08:51:39.017 Primary Thread ID: 1428 | 2020-11-12 08:51:39.017 Usage end date: 2020-12-13 | 2020-11-12 08:51:39.017 Enabled for: Advanced Features 2. | 2020-11-12 08:51:39.017 Enabled for: Sierra Chart Historical Data Service. | 2020-11-12 08:51:39.017 Enabled for: Delayed Denali Real-Time Exchange Data Feed. | 2020-11-12 08:51:39.017 Allow Support for Sierra Chart Data Feeds is enabled. | 2020-11-12 08:51:39.017 Current selected Data/Trading service: Rithmic Trading | 2020-11-12 08:51:39.017 Custom symbol settings values: enabled | 2020-11-12 08:51:39.017 Chart Update Interval: 500 | 2020-11-12 08:51:39.017 Intraday Data Storage Time Unit: 1 | 2020-11-12 08:51:39.017 Time Zone: -06:00:00 (CST-06CDT+01,M3.2.0/02:00,M11.1.0/02:00) | 2020-11-12 08:51:39.017 2020-11-12 07:51:39 Local computer time | 2020-11-12 08:51:39.017 2020-11-12 14:51:39 Local computer time in UTC | 2020-11-12 08:51:39.017 2020-11-12 08:51:39 Local computer time in SC Time Zone | 2020-11-12 08:51:39.017 2020-11-12 14:51:39 Server time in UTC | 2020-11-12 08:51:39.017 Local computer UTC time and Server UTC time difference: 1 seconds. | 2020-11-12 08:51:39.017 Program path: C:\SierraChart\ | 2020-11-12 08:51:39.017 Data Files path: C:\SierraChart\Data\ | 2020-11-12 08:51:39.017 OS Version Number: 10.0 | 2020-11-12 08:51:39.018 Locale Setting: C | 2020-11-12 08:51:39.018 DLLs: UserContributedStudies_64.dll | 2020-11-12 08:51:39.018 Allowed protected custom studies: | 2020-11-12 08:51:39.018 Checking for new symbol settings. Requested symbol settings MD5 for service code rithmic.trading. Request ID: 1. | 2020-11-12 08:51:39.032 HTTPS connection ID:1 to login.sierrachart.com:443 for request ID:1 (1) | Shutdown started. Waiting for graceful close. | 2020-11-12 08:51:39.076 HTTPS connection ID:1 to login.sierrachart.com:443 for request ID:1 (1) | Socket gracefully closed by remote side. | 2020-11-12 08:51:39.224 HTTPS connection ID:1 to login.sierrachart.com:443 for request ID:1 (1) | Closed. | 2020-11-12 08:51:39.224 Received 5 login tokens. | 2020-11-12 08:51:39.596 Symbol settings MD5 received. Request ID: 1. | 2020-11-12 08:51:39.742 Symbol settings are up-to-date for rithmic.trading. | 2020-11-12 08:51:39.742 Files to Open on Start up | Opening file: ExampleChartbook.cht | 2020-11-12 08:51:42.737 ESZ0-CME 1 Min #10 | Reloading chart. | 2020-11-12 08:51:42.894 ESZ0-CME #2 | Reloading chart. | 2020-11-12 08:51:42.926 ESZ0-CME #2 | StartDateTimeForLoadingOrderFills: 00:00:00 | 2020-11-12 08:51:42.927 ESZ0-CME 1 Min #10 | StartDateTimeForLoadingOrderFills: 2020-10-28 16:15:00 | 2020-11-12 08:51:43.017 Starting first historical Intraday data download. When complete another download will be done from the primary service. Symbol: ESZ0-CME | 2020-11-12 08:51:43.383 Starting DelayedDownloadMonitoringTimer | 2020-11-12 08:51:43.383 Starting HDTimeoutTimer | 2020-11-12 08:51:43.383 Added historical Intraday data request for ESZ0-CME to the queue. | 2020-11-12 08:51:43.408 Intraday data recording state for symbol ESZ0-CME is set to download 'Pending'. | 2020-11-12 08:51:43.408 Triggering next historical data download in queue. | 2020-11-12 08:51:43.408 HD Request # 1 | Downloading Intraday chart data for ESZ0-CME to the file ESZ0-CME.scid. Service: cme | 2020-11-12 08:51:43.413 Enabling compression for file: C:\SierraChart\Data\ESZ0-CME.scid. This may take a while. | 2020-11-12 08:51:43.413 * HD Request # 1 | Download start date-time: 2020-10-29 12:48:26.000000. File last date-time: 2020-10-29 12:48:26.118000 | 2020-11-12 08:51:43.413 HD Request # 1 | Using server: ds23.sierracharts.com port 10149 | 2020-11-12 08:51:43.413 Socket (1) | Creating socket. | 2020-11-12 08:51:43.476 Socket (1) | New receive buffer size: 5242880 | 2020-11-12 08:51:43.476 Socket (1) | Connecting to IP: 216.1.90.130. | 2020-11-12 08:51:43.476 HD Request # 1 | Setting DTC encoding to Binary VLS | 2020-11-12 08:51:43.616 HD Request # 1 | Sending historical data logon request message. | 2020-11-12 08:51:43.616 HD Request # 1 | Requesting Intraday data. Start date-time: 2020-10-29 12:48:26. Record interval: 1. Symbol: ESZ20 | 2020-11-12 08:51:44.144 HD Request # 1 | Decompressing data. | 2020-11-12 08:51:44.236 HD Request # 1 | Receiving Intraday data for ESZ0-CME starting at 2020-10-29 12:48:26.118000 | 2020-11-12 08:51:44.587 HD Request # 1 | Timestamp of first Intraday data file record written: 2020-10-29 12:48:26.118000 | 2020-11-12 08:51:44.919 Rithmic Trading | Port for executable: 64577 | 2020-11-12 08:51:44.953 Listening socket (1516). Port 64577 | Closed. | 2020-11-12 08:51:44.953 Rithmic Trading | Starting server: C:\SierraChart\Rim\DTCBridge.exe | 2020-11-12 08:51:44.954 Error creating process C:\SierraChart\Rim\DTCBridge.exe. Windows error code 2: The system cannot find the file specified. | 2020-11-12 08:51:44.954 * Rithmic Trading | Error running DTC server program C:\SierraChart\Rim\DTCBridge.exe. Rithmic bridge needs installing. To obtain the bridge files, go to: Rithmic Bridge Files and Updated TLS Certificate Files Needed for June 1, 2020 and Onward | 2020-11-12 08:51:44.954 * Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2020-11-12 08:51:44.954 Select 'File >> Disconnect' to prevent further connection attempts. | 2020-11-12 08:51:44.954 DTC Client socket (0) | CloseSocket call. | 2020-11-12 08:51:44.975 Rithmic Trading | Disconnected. | 2020-11-12 08:51:44.975 HD Request # 1 | Historical data for ESZ0-CME is delayed because connection to main data feed is not present. Current data will be received upon connection. | 2020-11-12 08:51:51.999 Socket (1) | CloseSocket call. | 2020-11-12 08:51:51.999 Socket (1) | 0 bytes remaining in receive buffer when socket closed. | 2020-11-12 08:51:51.999 Historical data download thread signaled to stop. | 2020-11-12 08:51:51.999 Socket (1) | Shutdown started. Waiting for graceful close. | 2020-11-12 08:51:51.999 HD Request # 1 | Received 560410 records from 2020-10-29 12:48:26.118000 to 2020-11-12 08:41:43.161000 (13.9 days) and wrote 560410 records for ESZ0-CME | 2020-11-12 08:51:51.999 HD Request # 1 | Completion time: 9s | 2020-11-12 08:51:52.000 HD Request # 1 | Intraday data download complete for ESZ0-CME. Unique request ID: 1 | 2020-11-12 08:51:52.000 Removing historical data download ID 1. | 2020-11-12 08:51:52.000 HD Request # 1 | Enabling Intraday chart updating for symbol. | 2020-11-12 08:51:52.000 Socket (1) | Socket gracefully closed by remote side. | 2020-11-12 08:51:52.062 Socket (1) | Closed. | 2020-11-12 08:51:52.062 Rithmic Trading | Using primary service for historical data for ESZ0-CME | 2020-11-12 08:51:52.067 HD Request # 1 | Download from primary service not started due to error. | 2020-11-12 08:51:52.067 Triggering next historical data download in queue. | 2020-11-12 08:51:52.067 Reloading charts due to time zone change. | 2020-11-12 07:52:58.666 ESZ0-CME 1 Min #10 | Reloading chart. | 2020-11-12 07:52:59.838 ESZ0-CME #2 | Reloading chart. | 2020-11-12 07:52:59.985 ESZ0-CME #2 | StartDateTimeForLoadingOrderFills: 00:00:00 | 2020-11-12 07:52:59.985 ESZ0-CME 1 Min #10 | StartDateTimeForLoadingOrderFills: 2020-11-11 16:15:00 | 2020-11-12 07:53:00.119 Rithmic Trading | Port for executable: 64673 | 2020-11-12 08:02:36.607 Listening socket (1740). Port 64673 | Closed. | 2020-11-12 08:02:36.607 Rithmic Trading | Starting server: C:\SierraChart\Rim\DTCBridge.exe | 2020-11-12 08:02:36.607 Error creating process C:\SierraChart\Rim\DTCBridge.exe. Windows error code 2: The system cannot find the file specified. | 2020-11-12 08:02:36.607 * Rithmic Trading | Error running DTC server program C:\SierraChart\Rim\DTCBridge.exe. Rithmic bridge needs installing. To obtain the bridge files, go to: Rithmic Bridge Files and Updated TLS Certificate Files Needed for June 1, 2020 and Onward | 2020-11-12 08:02:36.607 * Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2020-11-12 08:02:36.607 Select 'File >> Disconnect' to prevent further connection attempts. | 2020-11-12 08:02:36.607 DTC Client socket (0) | CloseSocket call. | 2020-11-12 08:02:36.643 Rithmic Trading | Disconnected. | 2020-11-12 08:02:36.643 HTTPS connection ID:1 to www.sierrachart.com:443 for request ID:1 (1) | Creating socket. Using TLS 1.2. | 2020-11-12 08:18:51.047 The message log has been sent to support. | 2020-11-12 08:18:51.047 * HTTPS connection ID:1 to www.sierrachart.com:443 for request ID:1 (1) | New receive buffer size: 5242880 | 2020-11-12 08:18:51.047 HTTPS connection ID:1 to www.sierrachart.com:443 for request ID:1 (1) | Connecting to IP: 46.4.97.203. | 2020-11-12 08:18:51.047 Sending of the Message Log is completed. The response was saved to C:\SierraChart\Data\MessageLogAnalysis.htm | 2020-11-12 08:18:53.088 HTTPS connection ID:1 to www.sierrachart.com:443 for request ID:1 (1) | CloseSocket call. | 2020-11-12 08:18:53.337 HTTPS connection ID:1 to www.sierrachart.com:443 for request ID:1 (1) | 0 bytes remaining in receive buffer when socket closed. | 2020-11-12 08:18:53.337 HTTPS connection ID:1 to www.sierrachart.com:443 for request ID:1 (1) | Shutdown started. Waiting for graceful close. | 2020-11-12 08:18:53.337 HTTPS connection ID:1 to www.sierrachart.com:443 for request ID:1 (1) | Socket gracefully closed by remote side. | 2020-11-12 08:18:53.487 HTTPS connection ID:1 to www.sierrachart.com:443 for request ID:1 (1) | Closed. | 2020-11-12 08:18:53.487 Rithmic Trading | Port for executable: 64929 | 2020-11-12 08:33:13.343 Listening socket (1680). Port 64929 | Closed. | 2020-11-12 08:33:13.343 Rithmic Trading | Starting server: C:\SierraChart\Rim\DTCBridge.exe | 2020-11-12 08:33:13.344 Error creating process C:\SierraChart\Rim\DTCBridge.exe. Windows error code 2: The system cannot find the file specified. | 2020-11-12 08:33:13.344 * Rithmic Trading | Error running DTC server program C:\SierraChart\Rim\DTCBridge.exe. Rithmic bridge needs installing. To obtain the bridge files, go to: Rithmic Bridge Files and Updated TLS Certificate Files Needed for June 1, 2020 and Onward | 2020-11-12 08:33:13.344 * Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2020-11-12 08:33:13.344 Select 'File >> Disconnect' to prevent further connection attempts. | 2020-11-12 08:33:13.344 DTC Client socket (0) | CloseSocket call. | 2020-11-12 08:33:13.382 Rithmic Trading | Disconnected. | 2020-11-12 08:33:13.382 Rithmic Trading | Port for executable: 65056 | 2020-11-12 08:46:57.273 Listening socket (2176). Port 65056 | Closed. | 2020-11-12 08:46:57.273 Rithmic Trading | Starting server: C:\SierraChart\Rim\DTCBridge.exe | 2020-11-12 08:46:57.274 Error creating process C:\SierraChart\Rim\DTCBridge.exe. Windows error code 2: The system cannot find the file specified. | 2020-11-12 08:46:57.274 * Rithmic Trading | Error running DTC server program C:\SierraChart\Rim\DTCBridge.exe. Rithmic bridge needs installing. To obtain the bridge files, go to: Rithmic Bridge Files and Updated TLS Certificate Files Needed for June 1, 2020 and Onward | 2020-11-12 08:46:57.274 * Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2020-11-12 08:46:57.274 Select 'File >> Disconnect' to prevent further connection attempts. | 2020-11-12 08:46:57.274 DTC Client socket (0) | CloseSocket call. | 2020-11-12 08:46:57.291 Rithmic Trading | Disconnected. | 2020-11-12 08:46:57.292 Rithmic Trading | Port for executable: 65058 | 2020-11-12 08:48:22.389 Listening socket (2372). Port 65058 | Closed. | 2020-11-12 08:48:22.389 Rithmic Trading | Starting server: C:\SierraChart\Rim\DTCBridge.exe | 2020-11-12 08:48:22.390 Error creating process C:\SierraChart\Rim\DTCBridge.exe. Windows error code 2: The system cannot find the file specified. | 2020-11-12 08:48:22.390 * Rithmic Trading | Error running DTC server program C:\SierraChart\Rim\DTCBridge.exe. Rithmic bridge needs installing. To obtain the bridge files, go to: Rithmic Bridge Files and Updated TLS Certificate Files Needed for June 1, 2020 and Onward | 2020-11-12 08:48:22.390 * Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2020-11-12 08:48:22.390 Select 'File >> Disconnect' to prevent further connection attempts. | 2020-11-12 08:48:22.390 DTC Client socket (0) | CloseSocket call. | 2020-11-12 08:48:22.424 Rithmic Trading | Disconnected. | 2020-11-12 08:48:22.424 Rithmic Trading | Port for executable: 65112 | 2020-11-12 08:57:53.063 Listening socket (2236). Port 65112 | Closed. | 2020-11-12 08:57:53.063 Rithmic Trading | Starting server: C:\SierraChart\Rim\DTCBridge.exe | 2020-11-12 08:57:53.064 Error creating process C:\SierraChart\Rim\DTCBridge.exe. Windows error code 2: The system cannot find the file specified. | 2020-11-12 08:57:53.064 * Rithmic Trading | Error running DTC server program C:\SierraChart\Rim\DTCBridge.exe. Rithmic bridge needs installing. To obtain the bridge files, go to: Rithmic Bridge Files and Updated TLS Certificate Files Needed for June 1, 2020 and Onward | 2020-11-12 08:57:53.064 * Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2020-11-12 08:57:53.064 Select 'File >> Disconnect' to prevent further connection attempts. | 2020-11-12 08:57:53.064 DTC Client socket (0) | CloseSocket call. | 2020-11-12 08:57:53.096 Rithmic Trading | Disconnected. | 2020-11-12 08:57:53.096 Rithmic Trading | Port for executable: 65114 | 2020-11-12 08:58:08.039 Listening socket (1728). Port 65114 | Closed. | 2020-11-12 08:58:08.039 Rithmic Trading | Starting server: C:\SierraChart\Rim\DTCBridge.exe | 2020-11-12 08:58:08.040 Error creating process C:\SierraChart\Rim\DTCBridge.exe. Windows error code 2: The system cannot find the file specified. | 2020-11-12 08:58:08.040 * Rithmic Trading | Error running DTC server program C:\SierraChart\Rim\DTCBridge.exe. Rithmic bridge needs installing. To obtain the bridge files, go to: Rithmic Bridge Files and Updated TLS Certificate Files Needed for June 1, 2020 and Onward | 2020-11-12 08:58:08.040 * Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2020-11-12 08:58:08.040 Select 'File >> Disconnect' to prevent further connection attempts. | 2020-11-12 08:58:08.040 DTC Client socket (0) | CloseSocket call. | 2020-11-12 08:58:08.073 Rithmic Trading | Disconnected. | 2020-11-12 08:58:08.073 I tried to install bridge files but could not find it on the page that is linked? |
[2020-11-12 18:20:17] |
John - SC Support - Posts: 37910 |
Sorry about that. This is where you will find the Bridge Files that you need to install: Rithmic Bridge Files For the most reliable, advanced, and zero cost futures order routing, use the Teton service: Sierra Chart Teton Futures Order Routing |
To post a message in this thread, you need to log in with your Sierra Chart account: