Post From: ACSIL TS Sequence during replay

[2015-11-21 16:04:09]
ejtrader - Posts: 688
SC team - Update on this:

On a second thought - If there is a larger bar - T&S data might not be sufficient to fill the real time bar when there is a reload.

So have implemented a hybrid (SCID + TS records) approach and all is good for what I wanted to do. No further help is needed on this.

screencast.com/t/ZXPhjExVyTj -- Historical replay mode

screencast.com/t/aCcMM5EkQ -- real time bar

However to make SC better in this space Would suggest the following. It would be your decision in the end whether to implement or not :)

- T&S records - start to populate from very first tick of the latest bar from the moment replay is started (very useful one)
- an ACSIL function to detect "forward/reverse" button press. (nice to have)
- Include "Sequence" as available T&S window column. (somewhat nice to have)


Thanks
Date Time Of Last Edit: 2015-11-21 18:12:45