Post From: ACSIL TS Sequence during replay

[2015-11-19 04:16:46]
ejtrader - Posts: 688
SC Team - On the similar topic - found an issue with latest version ( 1328) - where one of the T&S record being accounted incorrectly.

It appears like - 22:04:55.000 - record is being accounted in 22:05:00 bar - which should technically belong to prior bar. For reference - you can use the total volume.

For the last bar (22:05 - bar - the volume should have been 30 based on T&S records - where as in number bars as well as Compact Values - the volume shows up as 34 ).

screencast.com/t/UvJAvPXJig

Don't recall this issue in the past and - It appears like there seem to be a bug introduced recently related to this. Would you please review?

PS: I have tick data stored as well - no "combine option" in T&S data.

on one more occassion today - with this latest version - Noticed 0x0 for one of the records ( don't recall this issue in the past as well ).

screencast.com/t/0jbty2opb4


Thanks
Date Time Of Last Edit: 2015-11-19 04:20:22