Login Page - Create Account

Support Board


Date/Time: Mon, 16 Sep 2024 19:13:56 +0000



Post From: Long Entry and Short Exit | Short Entry and Long Exit

[2024-07-05 17:26:57]
Sawtooth - Posts: 4091
Is there any way to add logic to check if whether we really need a reversal?
Maybe, if your signals were at bar close.

Columns K-N are the signal columns, and intended to only have a TRUE/1 in individual rows, where the condition is TRUE in that bar, not the entire column of TRUE/1.
Use other Formula Columns, or open cells, for intermediate calculations.

Intrabar signals (Signal Only On Bar Close set to No) are frequently problematic, especially when using Reversals.
IMO, the default settings for these should be Yes.

The reason intrabar signals are frequently problematic is because a spreadsheet study cannot capture/retain/make persistent an intrabar signal.
Additionally, no intrabar signals are marked, only signals that occurred at close of bar, so you cannot tell what happened inside that bar with historical arrows.

Also, best practice is to not use row 2 for anything other than the label.
Row 1 in Formula Columns is open; use it instead. All of column H is also open.