Post From: Calculations of Footprint Calculated Values study

[2024-02-19 17:27:08]
RB2703 - Posts: 2
re: points B) and C)

Finish % is a percentage which will always be positive, similar to how volume will always be positive thus ignoring the "range down" coloring. If you are relying on the calculated values grid visually perhaps it makes sense to use multiple instances with different coloring types.

The finish % calculation in your example is correct. The last new h/l Δ must have been the -274 so there is a difference of 337 between -274 and 63 which is a 122.9% difference of finish delta and delta low

=ABS((barΔ-last new H/LΔ)/(last new h/lΔ))*100

=ABS((63--274)/(-274))*100