[2022-07-05 17:31:41]
John - SC Support - Posts: 36350
1. If you want to have the DOMs contained within the main Sierra Chart screen and then have that displayed in a certain monitor, then you would need to use a Sub-Instance that holds that Chartbook. Refer to the following:
File Menu: New Instance (File)

2. There is not a way to setup a single reset button that will work with the active chart. What you can do is to have separate Control Bar Buttons that control each individual DOM, so you would select a specific button to reset a specific DOM. You do this by selecting a different ACS Control Bar button number in the Volume by Price Reset Button Inputs. Refer to the following:
Volume By Price Reset Button

3. The only way to reset back to the original Volume by Price settings is to change the Volume by Price study itself and set the Inputs back to their original values. Or, if you have the study setup by default the way you want, then you could delete it and re-add it. Refer to the following for how to setup custom study defaults:
Chart Studies: Using Custom Default Study Settings
For the most reliable, advanced, and zero cost futures order routing, use the Teton service:
Sierra Chart Teton Futures Order Routing