WRT Post #9:


The plot is correct, it's just inverted.

But the plot is not correct, even if you invert it. If n = 2, the indicator should be zero for all values of sc.Index. You are looking at a Subgraph that is generated by random numbers that are beyond floating point precision.

Please see the attached spreadsheet, which I generated using n = 2. The only reason that you see a Subgraph that is not zero everywhere is that the calculated values of HP differ slightly from zero, when they should be exactly zero.
Date Time Of Last Edit: 2022-06-15 22:56:41
attachmentEBSWI_n=2.scss - Attached On 2022-06-15 21:56:47 UTC - Size: 5.84 KB - 343 views