[2021-08-18 16:40:45] |
John - SC Support - Posts: 38259 |
You have a number of issues. Starting from the first one we saw: Loading DLL: C:\SierraChart\SierraChartInstance_2\Data\PullStack.dll (PullStack_64.dll). Handle: 770000 | 2021-08-18 09:14:10.759
The advanced custom study C:\SierraChart\SierraChartInstance_2\Data\PullStack.dll needs to be recompiled to be used on this version: 2276 | 2021-08-18 09:14:10.759 * You need an updated version of the file PullStack_64.dll in order to continue to use it. Loading DLL: C:\SierraChart\SierraChartInstance_2\Data\sst_pulling_stacking.dll (sst_pulling_stacking_64.dll). Handle: b5f0000 | 2021-08-18 09:14:11.089
The advanced custom study C:\SierraChart\SierraChartInstance_2\Data\sst_pulling_stacking.dll needs to be recompiled to be used on this version: 2276 | 2021-08-18 09:14:11.089 * Same as above, you need a newer version of the file sst_pulling_stacking_64.dll Loading DLL: C:\SierraChart\SierraChartInstance_2\Data\sst_speed_blocks.dll (sst_speed_blocks_64.dll). Handle: bc30000 | 2021-08-18 09:14:11.129
The advanced custom study C:\SierraChart\SierraChartInstance_2\Data\sst_speed_blocks.dll needs to be recompiled to be used on this version: 2276 | 2021-08-18 09:14:11.129 * Same issue as above ones for sst_speed_blocks_64.dll Chart: ESU21-CME[M] 10 Sec #2 | Study: ATEAM - Signal Receiver Plot Study - Rectangles | The Signal Tag setting is empty. This is a required input. The study will not continue without a Signal Tag set. | 2021-08-18 09:19:51.946 *
Chart: ESU21-CME[M] 10 Sec #2 | Study: ATEAM - Signal Receiver Plot Study - Rectangles | This plot study ID#23 is not connected to the Signal Receiver Connection Study. Check the reference setting and the existence of the connection study. | 2021-08-18 09:19:51.946 * Chart: ESU21-CME[M] 10 Sec #2 | Study: ATEAM - Signal Receiver Plot Study - Rectangles | The Signal Tag setting is empty. This is a required input. The study will not continue without a Signal Tag set. | 2021-08-18 09:19:57.187 * Chart: ESU21-CME[M] 10 Sec #2 | Study: ATEAM - Signal Receiver Plot Study - Rectangles | This plot study ID#23 is not connected to the Signal Receiver Connection Study. Check the reference setting and the existence of the connection study. | 2021-08-18 09:19:57.187 * Chart: ESU21-CME[M] 10 Sec #2 | Study: ATEAM - Signal Receiver Plot Study - Rectangles | The Signal Tag setting is empty. This is a required input. The study will not continue without a Signal Tag set. | 2021-08-18 09:22:05.387 * Chart: ESU21-CME[M] 10 Sec #2 | Study: ATEAM - Signal Receiver Plot Study - Rectangles | This plot study ID#23 is not connected to the Signal Receiver Connection Study. | 2021-08-18 09:22:05.387 * Chart: ESU21-CME[M] 10 Sec #2 | Study: ATEAM - Signal Receiver Plot Study - Rectangles | This plot study is connected to the Signal Receiver Connection Study. | 2021-08-18 09:23:25.915 * Chart: ESU21-CME[M] 500 Trades #3 | Study: ATEAM - Signal Receiver Plot Study - Rectangles | This plot study is connected to the Signal Receiver Connection Study. | 2021-08-18 09:29:20.154 * Somehow you are missing something associated with the study ATEAM - Signal Receiver Plot Study - Rectangles. We do not know what this might be, so you would need to figure out why you are missing some inoformation. Warning: The Custom DLL study "sst_ateam_64.scsf_VolumeBen" has just caused a CPU exception. | 2021-08-18 10:08:41.173 *
This is a bad situation. You will need to remove where you have used the study sst_ateam_64.scsf_VolumeBen and restart Sierra Chart. We do not know the specific charts these are on. You will need to go through your charts and find the problem studies and remove them from each chart. Then get a hold of the producer of these studies and have them updated. For the most reliable, advanced, and zero cost futures order routing, use the Teton service: Sierra Chart Teton Futures Order Routing |