Post From: High / Low for the time period = extended: wrong start on the tick chart

[2020-10-08 12:55:51]
User112177 - Posts: 8
Hello User212764,
Session Times settings from the Chart Settings box?
Yep, just did, thanks for helping us out : )).
Old session ENDiNG time was 09:29:29, typo obvously - that's why I couldn't figure why "High-Low" for the day started at 09:26

When I've changed it to 09:30:00 or 09:29:59 - start time "Hi-Low Daily" bar "moved" from 09:26:51 to 09:29:48 [was 09:30:00 exactly on v 2150]

NOTE: 1-minute & 5-minute charts do NOT have this problem; daily graph starts at 09:30 [as expected] - doesn't matter 09:29:29 or 09:29:59 or 09:30:00
Attachment Deleted.
imagesc_settings_Session_times_OLD=092929.png / V - Attached On 2020-10-08 12:55:16 UTC - Size: 155.18 KB - 241 views
imagesc_settings_Session_times=092959.png / V - Attached On 2020-10-08 12:55:24 UTC - Size: 159.73 KB - 251 views