Connecting to Rithmic

View Count: 793

[2020-11-12 18:11:38]
Walker Zweifel - Posts: 1
Reading Internal Order ID file. | 2020-11-12 08:51:38.926
Reading Trade Orders file. | 2020-11-12 08:51:39.000
Reading Trade Positions file. | 2020-11-12 08:51:39.000
Reading Account Balance file. | 2020-11-12 08:51:39.000
UDPListener (1480). Port 22904 | Listening on UDP port 22904. | 2020-11-12 08:51:39.017
Software version: 2182 64-bit | 2020-11-12 08:51:39.017
Primary Thread ID: 1428 | 2020-11-12 08:51:39.017
Usage end date: 2020-12-13 | 2020-11-12 08:51:39.017
Enabled for: Advanced Features 2. | 2020-11-12 08:51:39.017
Enabled for: Sierra Chart Historical Data Service. | 2020-11-12 08:51:39.017
Enabled for: Delayed Denali Real-Time Exchange Data Feed. | 2020-11-12 08:51:39.017
Allow Support for Sierra Chart Data Feeds is enabled. | 2020-11-12 08:51:39.017
Current selected Data/Trading service: Rithmic Trading | 2020-11-12 08:51:39.017
Custom symbol settings values: enabled | 2020-11-12 08:51:39.017
Chart Update Interval: 500 | 2020-11-12 08:51:39.017
Intraday Data Storage Time Unit: 1 | 2020-11-12 08:51:39.017
Time Zone: -06:00:00 (CST-06CDT+01,M3.2.0/02:00,M11.1.0/02:00) | 2020-11-12 08:51:39.017
2020-11-12 07:51:39 Local computer time | 2020-11-12 08:51:39.017
2020-11-12 14:51:39 Local computer time in UTC | 2020-11-12 08:51:39.017
2020-11-12 08:51:39 Local computer time in SC Time Zone | 2020-11-12 08:51:39.017
2020-11-12 14:51:39 Server time in UTC | 2020-11-12 08:51:39.017
Local computer UTC time and Server UTC time difference: 1 seconds. | 2020-11-12 08:51:39.017
Program path: C:\SierraChart\ | 2020-11-12 08:51:39.017
Data Files path: C:\SierraChart\Data\ | 2020-11-12 08:51:39.017
OS Version Number: 10.0 | 2020-11-12 08:51:39.018
Locale Setting: C | 2020-11-12 08:51:39.018
DLLs: UserContributedStudies_64.dll | 2020-11-12 08:51:39.018
Allowed protected custom studies: | 2020-11-12 08:51:39.018

Checking for new symbol settings. Requested symbol settings MD5 for service code rithmic.trading. Request ID: 1. | 2020-11-12 08:51:39.032
HTTPS connection ID:1 to login.sierrachart.com:443 for request ID:1 (1) | Shutdown started. Waiting for graceful close. | 2020-11-12 08:51:39.076
HTTPS connection ID:1 to login.sierrachart.com:443 for request ID:1 (1) | Socket gracefully closed by remote side. | 2020-11-12 08:51:39.224
HTTPS connection ID:1 to login.sierrachart.com:443 for request ID:1 (1) | Closed. | 2020-11-12 08:51:39.224
Received 5 login tokens. | 2020-11-12 08:51:39.596
Symbol settings MD5 received. Request ID: 1. | 2020-11-12 08:51:39.742
Symbol settings are up-to-date for rithmic.trading. | 2020-11-12 08:51:39.742
Files to Open on Start up | Opening file: ExampleChartbook.cht | 2020-11-12 08:51:42.737
ESZ0-CME 1 Min #10 | Reloading chart. | 2020-11-12 08:51:42.894
ESZ0-CME #2 | Reloading chart. | 2020-11-12 08:51:42.926
ESZ0-CME #2 | StartDateTimeForLoadingOrderFills: 00:00:00 | 2020-11-12 08:51:42.927
ESZ0-CME 1 Min #10 | StartDateTimeForLoadingOrderFills: 2020-10-28 16:15:00 | 2020-11-12 08:51:43.017
Starting first historical Intraday data download. When complete another download will be done from the primary service. Symbol: ESZ0-CME | 2020-11-12 08:51:43.383
Starting DelayedDownloadMonitoringTimer | 2020-11-12 08:51:43.383
Starting HDTimeoutTimer | 2020-11-12 08:51:43.383
Added historical Intraday data request for ESZ0-CME to the queue. | 2020-11-12 08:51:43.408
Intraday data recording state for symbol ESZ0-CME is set to download 'Pending'. | 2020-11-12 08:51:43.408
Triggering next historical data download in queue. | 2020-11-12 08:51:43.408
HD Request # 1 | Downloading Intraday chart data for ESZ0-CME to the file ESZ0-CME.scid. Service: cme | 2020-11-12 08:51:43.413
Enabling compression for file: C:\SierraChart\Data\ESZ0-CME.scid. This may take a while. | 2020-11-12 08:51:43.413 *
HD Request # 1 | Download start date-time: 2020-10-29 12:48:26.000000. File last date-time: 2020-10-29 12:48:26.118000 | 2020-11-12 08:51:43.413
HD Request # 1 | Using server: ds23.sierracharts.com port 10149 | 2020-11-12 08:51:43.413
Socket (1) | Creating socket. | 2020-11-12 08:51:43.476
Socket (1) | New receive buffer size: 5242880 | 2020-11-12 08:51:43.476
Socket (1) | Connecting to IP: 216.1.90.130. | 2020-11-12 08:51:43.476
HD Request # 1 | Setting DTC encoding to Binary VLS | 2020-11-12 08:51:43.616
HD Request # 1 | Sending historical data logon request message. | 2020-11-12 08:51:43.616
HD Request # 1 | Requesting Intraday data. Start date-time: 2020-10-29 12:48:26. Record interval: 1. Symbol: ESZ20 | 2020-11-12 08:51:44.144
HD Request # 1 | Decompressing data. | 2020-11-12 08:51:44.236
HD Request # 1 | Receiving Intraday data for ESZ0-CME starting at 2020-10-29 12:48:26.118000 | 2020-11-12 08:51:44.587
HD Request # 1 | Timestamp of first Intraday data file record written: 2020-10-29 12:48:26.118000 | 2020-11-12 08:51:44.919

Rithmic Trading | Port for executable: 64577 | 2020-11-12 08:51:44.953
Listening socket (1516). Port 64577 | Closed. | 2020-11-12 08:51:44.953
Rithmic Trading | Starting server: C:\SierraChart\Rim\DTCBridge.exe | 2020-11-12 08:51:44.954
Error creating process C:\SierraChart\Rim\DTCBridge.exe. Windows error code 2: The system cannot find the file specified. | 2020-11-12 08:51:44.954 *
Rithmic Trading | Error running DTC server program C:\SierraChart\Rim\DTCBridge.exe. Rithmic bridge needs installing. To obtain the bridge files, go to: Rithmic Bridge Files and Updated TLS Certificate Files Needed for June 1, 2020 and Onward | 2020-11-12 08:51:44.954 *
Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2020-11-12 08:51:44.954
Select 'File >> Disconnect' to prevent further connection attempts. | 2020-11-12 08:51:44.954
DTC Client socket (0) | CloseSocket call. | 2020-11-12 08:51:44.975
Rithmic Trading | Disconnected. | 2020-11-12 08:51:44.975
HD Request # 1 | Historical data for ESZ0-CME is delayed because connection to main data feed is not present. Current data will be received upon connection. | 2020-11-12 08:51:51.999
Socket (1) | CloseSocket call. | 2020-11-12 08:51:51.999
Socket (1) | 0 bytes remaining in receive buffer when socket closed. | 2020-11-12 08:51:51.999
Historical data download thread signaled to stop. | 2020-11-12 08:51:51.999
Socket (1) | Shutdown started. Waiting for graceful close. | 2020-11-12 08:51:51.999
HD Request # 1 | Received 560410 records from 2020-10-29 12:48:26.118000 to 2020-11-12 08:41:43.161000 (13.9 days) and wrote 560410 records for ESZ0-CME | 2020-11-12 08:51:51.999
HD Request # 1 | Completion time: 9s | 2020-11-12 08:51:52.000
HD Request # 1 | Intraday data download complete for ESZ0-CME. Unique request ID: 1 | 2020-11-12 08:51:52.000
Removing historical data download ID 1. | 2020-11-12 08:51:52.000
HD Request # 1 | Enabling Intraday chart updating for symbol. | 2020-11-12 08:51:52.000
Socket (1) | Socket gracefully closed by remote side. | 2020-11-12 08:51:52.062
Socket (1) | Closed. | 2020-11-12 08:51:52.062
Rithmic Trading | Using primary service for historical data for ESZ0-CME | 2020-11-12 08:51:52.067
HD Request # 1 | Download from primary service not started due to error. | 2020-11-12 08:51:52.067

Triggering next historical data download in queue. | 2020-11-12 08:51:52.067
Reloading charts due to time zone change. | 2020-11-12 07:52:58.666
ESZ0-CME 1 Min #10 | Reloading chart. | 2020-11-12 07:52:59.838
ESZ0-CME #2 | Reloading chart. | 2020-11-12 07:52:59.985
ESZ0-CME #2 | StartDateTimeForLoadingOrderFills: 00:00:00 | 2020-11-12 07:52:59.985
ESZ0-CME 1 Min #10 | StartDateTimeForLoadingOrderFills: 2020-11-11 16:15:00 | 2020-11-12 07:53:00.119

Rithmic Trading | Port for executable: 64673 | 2020-11-12 08:02:36.607
Listening socket (1740). Port 64673 | Closed. | 2020-11-12 08:02:36.607
Rithmic Trading | Starting server: C:\SierraChart\Rim\DTCBridge.exe | 2020-11-12 08:02:36.607
Error creating process C:\SierraChart\Rim\DTCBridge.exe. Windows error code 2: The system cannot find the file specified. | 2020-11-12 08:02:36.607 *
Rithmic Trading | Error running DTC server program C:\SierraChart\Rim\DTCBridge.exe. Rithmic bridge needs installing. To obtain the bridge files, go to: Rithmic Bridge Files and Updated TLS Certificate Files Needed for June 1, 2020 and Onward | 2020-11-12 08:02:36.607 *
Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2020-11-12 08:02:36.607
Select 'File >> Disconnect' to prevent further connection attempts. | 2020-11-12 08:02:36.607
DTC Client socket (0) | CloseSocket call. | 2020-11-12 08:02:36.643
Rithmic Trading | Disconnected. | 2020-11-12 08:02:36.643
HTTPS connection ID:1 to www.sierrachart.com:443 for request ID:1 (1) | Creating socket. Using TLS 1.2. | 2020-11-12 08:18:51.047
The message log has been sent to support. | 2020-11-12 08:18:51.047 *
HTTPS connection ID:1 to www.sierrachart.com:443 for request ID:1 (1) | New receive buffer size: 5242880 | 2020-11-12 08:18:51.047
HTTPS connection ID:1 to www.sierrachart.com:443 for request ID:1 (1) | Connecting to IP: 46.4.97.203. | 2020-11-12 08:18:51.047
Sending of the Message Log is completed. The response was saved to C:\SierraChart\Data\MessageLogAnalysis.htm | 2020-11-12 08:18:53.088
HTTPS connection ID:1 to www.sierrachart.com:443 for request ID:1 (1) | CloseSocket call. | 2020-11-12 08:18:53.337
HTTPS connection ID:1 to www.sierrachart.com:443 for request ID:1 (1) | 0 bytes remaining in receive buffer when socket closed. | 2020-11-12 08:18:53.337
HTTPS connection ID:1 to www.sierrachart.com:443 for request ID:1 (1) | Shutdown started. Waiting for graceful close. | 2020-11-12 08:18:53.337
HTTPS connection ID:1 to www.sierrachart.com:443 for request ID:1 (1) | Socket gracefully closed by remote side. | 2020-11-12 08:18:53.487
HTTPS connection ID:1 to www.sierrachart.com:443 for request ID:1 (1) | Closed. | 2020-11-12 08:18:53.487

Rithmic Trading | Port for executable: 64929 | 2020-11-12 08:33:13.343
Listening socket (1680). Port 64929 | Closed. | 2020-11-12 08:33:13.343
Rithmic Trading | Starting server: C:\SierraChart\Rim\DTCBridge.exe | 2020-11-12 08:33:13.344
Error creating process C:\SierraChart\Rim\DTCBridge.exe. Windows error code 2: The system cannot find the file specified. | 2020-11-12 08:33:13.344 *
Rithmic Trading | Error running DTC server program C:\SierraChart\Rim\DTCBridge.exe. Rithmic bridge needs installing. To obtain the bridge files, go to: Rithmic Bridge Files and Updated TLS Certificate Files Needed for June 1, 2020 and Onward | 2020-11-12 08:33:13.344 *
Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2020-11-12 08:33:13.344
Select 'File >> Disconnect' to prevent further connection attempts. | 2020-11-12 08:33:13.344
DTC Client socket (0) | CloseSocket call. | 2020-11-12 08:33:13.382
Rithmic Trading | Disconnected. | 2020-11-12 08:33:13.382

Rithmic Trading | Port for executable: 65056 | 2020-11-12 08:46:57.273
Listening socket (2176). Port 65056 | Closed. | 2020-11-12 08:46:57.273
Rithmic Trading | Starting server: C:\SierraChart\Rim\DTCBridge.exe | 2020-11-12 08:46:57.274
Error creating process C:\SierraChart\Rim\DTCBridge.exe. Windows error code 2: The system cannot find the file specified. | 2020-11-12 08:46:57.274 *
Rithmic Trading | Error running DTC server program C:\SierraChart\Rim\DTCBridge.exe. Rithmic bridge needs installing. To obtain the bridge files, go to: Rithmic Bridge Files and Updated TLS Certificate Files Needed for June 1, 2020 and Onward | 2020-11-12 08:46:57.274 *
Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2020-11-12 08:46:57.274
Select 'File >> Disconnect' to prevent further connection attempts. | 2020-11-12 08:46:57.274
DTC Client socket (0) | CloseSocket call. | 2020-11-12 08:46:57.291
Rithmic Trading | Disconnected. | 2020-11-12 08:46:57.292

Rithmic Trading | Port for executable: 65058 | 2020-11-12 08:48:22.389
Listening socket (2372). Port 65058 | Closed. | 2020-11-12 08:48:22.389
Rithmic Trading | Starting server: C:\SierraChart\Rim\DTCBridge.exe | 2020-11-12 08:48:22.390
Error creating process C:\SierraChart\Rim\DTCBridge.exe. Windows error code 2: The system cannot find the file specified. | 2020-11-12 08:48:22.390 *
Rithmic Trading | Error running DTC server program C:\SierraChart\Rim\DTCBridge.exe. Rithmic bridge needs installing. To obtain the bridge files, go to: Rithmic Bridge Files and Updated TLS Certificate Files Needed for June 1, 2020 and Onward | 2020-11-12 08:48:22.390 *
Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2020-11-12 08:48:22.390
Select 'File >> Disconnect' to prevent further connection attempts. | 2020-11-12 08:48:22.390
DTC Client socket (0) | CloseSocket call. | 2020-11-12 08:48:22.424
Rithmic Trading | Disconnected. | 2020-11-12 08:48:22.424

Rithmic Trading | Port for executable: 65112 | 2020-11-12 08:57:53.063
Listening socket (2236). Port 65112 | Closed. | 2020-11-12 08:57:53.063
Rithmic Trading | Starting server: C:\SierraChart\Rim\DTCBridge.exe | 2020-11-12 08:57:53.064
Error creating process C:\SierraChart\Rim\DTCBridge.exe. Windows error code 2: The system cannot find the file specified. | 2020-11-12 08:57:53.064 *
Rithmic Trading | Error running DTC server program C:\SierraChart\Rim\DTCBridge.exe. Rithmic bridge needs installing. To obtain the bridge files, go to: Rithmic Bridge Files and Updated TLS Certificate Files Needed for June 1, 2020 and Onward | 2020-11-12 08:57:53.064 *
Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2020-11-12 08:57:53.064
Select 'File >> Disconnect' to prevent further connection attempts. | 2020-11-12 08:57:53.064
DTC Client socket (0) | CloseSocket call. | 2020-11-12 08:57:53.096
Rithmic Trading | Disconnected. | 2020-11-12 08:57:53.096

Rithmic Trading | Port for executable: 65114 | 2020-11-12 08:58:08.039
Listening socket (1728). Port 65114 | Closed. | 2020-11-12 08:58:08.039
Rithmic Trading | Starting server: C:\SierraChart\Rim\DTCBridge.exe | 2020-11-12 08:58:08.040
Error creating process C:\SierraChart\Rim\DTCBridge.exe. Windows error code 2: The system cannot find the file specified. | 2020-11-12 08:58:08.040 *
Rithmic Trading | Error running DTC server program C:\SierraChart\Rim\DTCBridge.exe. Rithmic bridge needs installing. To obtain the bridge files, go to: Rithmic Bridge Files and Updated TLS Certificate Files Needed for June 1, 2020 and Onward | 2020-11-12 08:58:08.040 *
Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2020-11-12 08:58:08.040
Select 'File >> Disconnect' to prevent further connection attempts. | 2020-11-12 08:58:08.040
DTC Client socket (0) | CloseSocket call. | 2020-11-12 08:58:08.073
Rithmic Trading | Disconnected. | 2020-11-12 08:58:08.073

I tried to install bridge files but could not find it on the page that is linked?
[2020-11-12 18:20:17]
John - SC Support - Posts: 37916
Sorry about that. This is where you will find the Bridge Files that you need to install: