[2018-09-08 20:26:03] |
User14682 - Posts: 83 |
How to I ask the system to exit only 1 at +500 when the position is 2? can I only remove half of a position if quantity is set at 2?? ,AND($J$10>500) Thanks Brandon |
[2018-09-08 21:29:03] |
Sawtooth - Posts: 4158 |
If you are using L3 and N3 for your exits, you can use J82/J83 for the exit quantity.
|
[2018-09-09 20:06:06] |
User14682 - Posts: 83 |
thanks.. I think I got it
|
[2018-09-09 20:21:02] |
User14682 - Posts: 83 |
I cant get it to work... Example?
|
[2018-09-09 21:13:17] |
Sawtooth - Posts: 4158 |
1. L3/N3 goes true when J10 > 500: =AND($J$8<>0,$J$10>500) 2. J82 is 1 to activate J83: =1 3. J83 is the exit quantity using a formula returning 1: =ABS(J8)/2 |