Support Board
Date/Time: Sat, 11 Jan 2025 17:36:52 +0000
Data Feeds: AMP will no longer support TT Fix Connection
View Count: 1637
[2016-12-09 09:21:49] |
tobi - Posts: 351 |
I received this message from AMP: This is a notice to our customers currently enabled for Sierra Chart - TT Datafeed. We are in the process of retiring the TT FIX Datafeed. Please fill out this form to change your datafeed from TT to either CQG or Rithmic. Sierra Chart - TT FIX connection will expire Dec. 30, 2016. I now have to decide between these data feeds: 1. CQG 2. Rithmic 3. Sierra Chart I'm daytrading the Dax and NQ. Important are speed, accuracy and reliability of the data feed. Could you please give me an advice which one the choose. What would be the advantages towards Sierra's datafeed? |
[2016-12-09 09:52:08] |
Sierra Chart Engineering - Posts: 104368 |
1. We generally will prefer CQG for technical integration reasons. You can use the CQG data feed or use the Sierra Chart Exchange Data Feed. See how you go with the CQG data feed, and if you have any issues we recommend using the Sierra Chart Exchange Data Feed: Sierra Chart Exchange Data Feed You may want to consider using our data feed sometime in January. At that time it will offer 20 levels of market depth for EUREX. Currently only 10 levels are provided. Sierra Chart Support - Engineering Level Your definitive source for support. Other responses are from users. Try to keep your questions brief and to the point. Be aware of support policy: https://www.sierrachart.com/index.php?l=PostingInformation.php#GeneralInformation For the most reliable, advanced, and zero cost futures order routing, *change* to the Teton service: Sierra Chart Teton Futures Order Routing |
[2016-12-10 06:00:53] |
tobi - Posts: 351 |
One additional question: Is the reason that AMP is retiring the TT FIX datafeed, that TT came up with the new TT-Web? Will it be possible that Sierra can use this (new?) datafeed from TT? |
[2016-12-10 06:39:03] |
Sierra Chart Engineering - Posts: 104368 |
We do not know the reason. And Sierra Chart will not be using any new data feed. This is completely out of the question.
Sierra Chart Support - Engineering Level Your definitive source for support. Other responses are from users. Try to keep your questions brief and to the point. Be aware of support policy: https://www.sierrachart.com/index.php?l=PostingInformation.php#GeneralInformation For the most reliable, advanced, and zero cost futures order routing, *change* to the Teton service: Sierra Chart Teton Futures Order Routing |
[2016-12-11 10:35:11] |
tobi - Posts: 351 |
Comparing CQG over AMP and Sierra Chart datafeeds (Eurex and CME bundle), are there any differences regarding their speed and reliability? Regarding speed, this is possibly hardly recognizable but measurable? The question only refers to charting since for trading/order-entry I'm using X_Trader from TT.
|
[2016-12-11 18:59:16] |
Sierra Chart Engineering - Posts: 104368 |
For speed and reliability for the CME data we would recommend the Sierra Chart Data Feed. But most of the time you are not going to notice any difference. For EUREX, continue to use CQG but we will have a better EUREX feed out in about a month or two. Sierra Chart Support - Engineering Level Your definitive source for support. Other responses are from users. Try to keep your questions brief and to the point. Be aware of support policy: https://www.sierrachart.com/index.php?l=PostingInformation.php#GeneralInformation For the most reliable, advanced, and zero cost futures order routing, *change* to the Teton service: Sierra Chart Teton Futures Order Routing |
[2016-12-12 16:24:42] |
tobi - Posts: 351 |
Regarding the EUREX feed, is this the only thing that is going to change You may want to consider using our data feed sometime in January. At that time it will offer 20 levels of market depth for EUREX. Currently only 10 levels are provided
or will there also be other additions/improvements? Maybe you can give some more details?
|
[2016-12-12 16:45:20] |
Sierra Chart Engineering - Posts: 104368 |
No further details. No other changes.
Sierra Chart Support - Engineering Level Your definitive source for support. Other responses are from users. Try to keep your questions brief and to the point. Be aware of support policy: https://www.sierrachart.com/index.php?l=PostingInformation.php#GeneralInformation For the most reliable, advanced, and zero cost futures order routing, *change* to the Teton service: Sierra Chart Teton Futures Order Routing |
[2016-12-12 17:03:35] |
tobi - Posts: 351 |
If market depth levels are not relevant for ones trading, would you still recommend CQG or then the same statement as for the CME feed? Sorry for these further questions, but I want to make a long term desicion on this. Date Time Of Last Edit: 2016-12-12 17:04:01
|
[2016-12-12 17:15:32] |
Sierra Chart Engineering - Posts: 104368 |
We think you are fine using EUREX through CQG. There is no need to use the Sierra Chart Exchange Data Feed for that. Sierra Chart Support - Engineering Level Your definitive source for support. Other responses are from users. Try to keep your questions brief and to the point. Be aware of support policy: https://www.sierrachart.com/index.php?l=PostingInformation.php#GeneralInformation For the most reliable, advanced, and zero cost futures order routing, *change* to the Teton service: Sierra Chart Teton Futures Order Routing |
[2016-12-12 17:52:34] |
User538063 - Posts: 3 |
I switched over from AMP/TTnet to Rithmic just today. I changed the Data Service settings to Rithmic and was able to connect successfully. However, after I save my settings and log out, the SC program defaults back to AMP/TTnet on subsequent login attempts. Each time I log into SC, I have to change the data service back to Rithmic. I tried downloading a 2nd copy of SC, but the same problem exists in that copy. (It seems that the AMP/TTnet connection is somehow linked to my SC login credentials). How do I get the program to default to Rithmic instead of AMP/TTnet? (message log): Reading Internal Order ID file. | 2016-12-12 17:36:12 Reading Trade Orders file. | 2016-12-12 17:36:12 Reading Trade Positions file. | 2016-12-12 17:36:12 Software version: 1495 | 2016-12-12 17:36:12 Uses New Spreadsheets | 2016-12-12 17:36:12 Enabled for: Advanced Features. | 2016-12-12 17:36:12 Enabled for: Sierra Chart Historical Data Service. | 2016-12-12 17:36:12 Allow Support for Sierra Chart Data Feeds is enabled. | 2016-12-12 17:36:12 Current selected Data/Trading service: AMP/TTNet | 2016-12-12 17:36:12 Chart Update Interval: 500 | 2016-12-12 17:36:12 Data/Trade Service Settings automatically set. | 2016-12-12 17:36:12 Time Zone: +00:00:00 (UTC+00) | 2016-12-12 17:36:12 2016-12-12 09:36:16 Local computer time | 2016-12-12 17:36:12 2016-12-12 17:36:16 Local computer time in UTC | 2016-12-12 17:36:12 2016-12-12 17:36:16 Local computer time in SC Time Zone | 2016-12-12 17:36:12 2016-12-12 17:36:15 Server time in UTC | 2016-12-12 17:36:12 Local computer UTC time and Server UTC time difference: 0 seconds. | 2016-12-12 17:36:12 Program path: C:\SierraChart AMP R\ | 2016-12-12 17:36:12 Data Files path: C:\SierraChart AMP R\Data\ | 2016-12-12 17:36:12 OS Version Number: 6.2 | 2016-12-12 17:36:12 Locale Setting: C | 2016-12-12 17:36:12 Checking for new symbol settings for tt | 2016-12-12 17:36:12 HTTPS connection to www.sierrachart.com:443 (0) | Resolved address sierrachart.com to IP 5.9.8.236. | 2016-12-12 17:36:12 HTTPS connection to www.sierrachart.com:443 (3) | Connected. | 2016-12-12 17:36:12 HTTPS connection to www.sierrachart.com:443 (3) | Starting TLS 1.2 connection. | 2016-12-12 17:36:12 HTTPS connection to www.sierrachart.com:443 (3) | SSL connection established. | 2016-12-12 17:36:17 Requesting symbol settings for tt. Overwrite = on. | 2016-12-12 17:36:17 Symbol settings received. | 2016-12-12 17:36:18 Processed 813 symbol settings. | 2016-12-12 17:36:18 AMP/TTNet | Connecting. | 2016-12-12 17:36:21 TT FIX Data | Connecting to 12.41.48.53. Port 10501 | 2016-12-12 17:36:21 TT FIX Data socket (4) | Connected. | 2016-12-12 17:36:21 TT FIX Data: Sending the Logon message. | 2016-12-12 17:36:21 TT FIX Data: Received a FIX message missing required field TargetCompID <56>. | 2016-12-12 17:36:21 * FIX Message: 8=FIX.4.29=0021135=549=TT_PRICE34=152=20161212-17:36:21.51358=Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator.18000=110=181 | 2016-12-12 17:36:21 * TT FIX Data: Received a Logout message. Text = Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator. | 2016-12-12 17:36:21 TT FIX Data: Sending a Logout message. Text = Received Logout message. | 2016-12-12 17:36:21 TT FIX Data socket (4) | Shutdown and closed. | 2016-12-12 17:36:21 TT FIX Data: Disconnected. | 2016-12-12 17:36:21 Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2016-12-12 17:36:21 To prevent further connection attempts, select 'File >> Disconnect'. | 2016-12-12 17:36:21 AMP/TTNet | Disconnected. | 2016-12-12 17:36:21 Will reconnect to the server in 3.0 seconds. Select 'File >> Disconnect' to prevent further connection attempts. | 2016-12-12 17:36:21 HTTPS connection to www.sierrachart.com:443 (3) | SSL connection closed by remote side. | 2016-12-12 17:36:23 HTTPS connection to www.sierrachart.com:443 (3) | Connection gracefully closed by remote side. | 2016-12-12 17:36:23 HTTPS connection to www.sierrachart.com:443 (3) | SSL object has been freed. SSL state is now disconnected. | 2016-12-12 17:36:23 HTTPS connection to www.sierrachart.com:443 (3) | Shutdown and closed. | 2016-12-12 17:36:23 AMP/TTNet | Connecting. | 2016-12-12 17:36:24 TT FIX Data | Connecting to 12.41.48.53. Port 10501 | 2016-12-12 17:36:24 TT FIX Data socket (5) | Connected. | 2016-12-12 17:36:24 TT FIX Data: Sending the Logon message. | 2016-12-12 17:36:25 TT FIX Data: Received a FIX message missing required field TargetCompID <56>. | 2016-12-12 17:36:25 * FIX Message: 8=FIX.4.29=0021135=549=TT_PRICE34=152=20161212-17:36:24.90058=Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator.18000=110=184 | 2016-12-12 17:36:25 * TT FIX Data: Received a Logout message. Text = Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator. | 2016-12-12 17:36:25 TT FIX Data: Sending a Logout message. Text = Received Logout message. | 2016-12-12 17:36:25 TT FIX Data socket (5) | Shutdown and closed. | 2016-12-12 17:36:25 TT FIX Data: Disconnected. | 2016-12-12 17:36:25 Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2016-12-12 17:36:25 To prevent further connection attempts, select 'File >> Disconnect'. | 2016-12-12 17:36:25 AMP/TTNet | Disconnected. | 2016-12-12 17:36:25 Will reconnect to the server in 3.0 seconds. Select 'File >> Disconnect' to prevent further connection attempts. | 2016-12-12 17:36:25 AMP/TTNet | Connecting. | 2016-12-12 17:36:28 TT FIX Data | Connecting to 12.41.48.53. Port 10501 | 2016-12-12 17:36:28 TT FIX Data socket (6) | Connected. | 2016-12-12 17:36:28 TT FIX Data: Sending the Logon message. | 2016-12-12 17:36:28 TT FIX Data: Received a FIX message missing required field TargetCompID <56>. | 2016-12-12 17:36:28 * FIX Message: 8=FIX.4.29=0021135=549=TT_PRICE34=152=20161212-17:36:28.29158=Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator.18000=110=191 | 2016-12-12 17:36:28 * TT FIX Data: Received a Logout message. Text = Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator. | 2016-12-12 17:36:28 TT FIX Data: Sending a Logout message. Text = Received Logout message. | 2016-12-12 17:36:28 TT FIX Data socket (6) | Shutdown and closed. | 2016-12-12 17:36:28 TT FIX Data: Disconnected. | 2016-12-12 17:36:28 Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2016-12-12 17:36:28 To prevent further connection attempts, select 'File >> Disconnect'. | 2016-12-12 17:36:28 AMP/TTNet | Disconnected. | 2016-12-12 17:36:28 Will reconnect to the server in 3.0 seconds. Select 'File >> Disconnect' to prevent further connection attempts. | 2016-12-12 17:36:28 AMP/TTNet | Connecting. | 2016-12-12 17:36:31 TT FIX Data | Connecting to 12.41.48.53. Port 10501 | 2016-12-12 17:36:31 TT FIX Data socket (7) | Connected. | 2016-12-12 17:36:31 TT FIX Data: Sending the Logon message. | 2016-12-12 17:36:31 TT FIX Data: Received a FIX message missing required field TargetCompID <56>. | 2016-12-12 17:36:32 * FIX Message: 8=FIX.4.29=0021135=549=TT_PRICE34=152=20161212-17:36:31.66058=Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator.18000=110=185 | 2016-12-12 17:36:32 * TT FIX Data: Received a Logout message. Text = Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator. | 2016-12-12 17:36:32 TT FIX Data: Sending a Logout message. Text = Received Logout message. | 2016-12-12 17:36:32 TT FIX Data socket (7) | Shutdown and closed. | 2016-12-12 17:36:32 TT FIX Data: Disconnected. | 2016-12-12 17:36:32 Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2016-12-12 17:36:32 To prevent further connection attempts, select 'File >> Disconnect'. | 2016-12-12 17:36:32 AMP/TTNet | Disconnected. | 2016-12-12 17:36:32 Will reconnect to the server in 3.0 seconds. Select 'File >> Disconnect' to prevent further connection attempts. | 2016-12-12 17:36:32 AMP/TTNet | Connecting. | 2016-12-12 17:36:35 TT FIX Data | Connecting to 12.41.48.53. Port 10501 | 2016-12-12 17:36:35 TT FIX Data socket (8) | Connected. | 2016-12-12 17:36:35 TT FIX Data: Sending the Logon message. | 2016-12-12 17:36:35 TT FIX Data: Received a FIX message missing required field TargetCompID <56>. | 2016-12-12 17:36:35 * FIX Message: 8=FIX.4.29=0021135=549=TT_PRICE34=152=20161212-17:36:35.03958=Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator.18000=110=189 | 2016-12-12 17:36:35 * TT FIX Data: Received a Logout message. Text = Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator. | 2016-12-12 17:36:35 TT FIX Data: Sending a Logout message. Text = Received Logout message. | 2016-12-12 17:36:35 TT FIX Data socket (8) | Shutdown and closed. | 2016-12-12 17:36:35 TT FIX Data: Disconnected. | 2016-12-12 17:36:35 Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2016-12-12 17:36:35 To prevent further connection attempts, select 'File >> Disconnect'. | 2016-12-12 17:36:35 AMP/TTNet | Disconnected. | 2016-12-12 17:36:35 Will reconnect to the server in 3.0 seconds. Select 'File >> Disconnect' to prevent further connection attempts. | 2016-12-12 17:36:35 AMP/TTNet | Connecting. | 2016-12-12 17:36:38 TT FIX Data | Connecting to 12.41.48.53. Port 10501 | 2016-12-12 17:36:38 TT FIX Data socket (9) | Connected. | 2016-12-12 17:36:38 TT FIX Data: Sending the Logon message. | 2016-12-12 17:36:38 TT FIX Data: Received a FIX message missing required field TargetCompID <56>. | 2016-12-12 17:36:38 * FIX Message: 8=FIX.4.29=0021135=549=TT_PRICE34=152=20161212-17:36:38.41258=Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator.18000=110=187 | 2016-12-12 17:36:38 * TT FIX Data: Received a Logout message. Text = Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator. | 2016-12-12 17:36:38 TT FIX Data: Sending a Logout message. Text = Received Logout message. | 2016-12-12 17:36:38 TT FIX Data socket (9) | Shutdown and closed. | 2016-12-12 17:36:38 TT FIX Data: Disconnected. | 2016-12-12 17:36:38 Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2016-12-12 17:36:38 To prevent further connection attempts, select 'File >> Disconnect'. | 2016-12-12 17:36:38 AMP/TTNet | Disconnected. | 2016-12-12 17:36:38 Will reconnect to the server in 3.0 seconds. Select 'File >> Disconnect' to prevent further connection attempts. | 2016-12-12 17:36:38 AMP/TTNet | Connecting. | 2016-12-12 17:36:41 TT FIX Data | Connecting to 12.41.48.53. Port 10501 | 2016-12-12 17:36:41 TT FIX Data socket (10) | Connected. | 2016-12-12 17:36:41 TT FIX Data: Sending the Logon message. | 2016-12-12 17:36:42 TT FIX Data: Received a FIX message missing required field TargetCompID <56>. | 2016-12-12 17:36:42 * FIX Message: 8=FIX.4.29=0021135=549=TT_PRICE34=152=20161212-17:36:41.78458=Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator.18000=110=193 | 2016-12-12 17:36:42 * TT FIX Data: Received a Logout message. Text = Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator. | 2016-12-12 17:36:42 TT FIX Data: Sending a Logout message. Text = Received Logout message. | 2016-12-12 17:36:42 TT FIX Data socket (10) | Shutdown and closed. | 2016-12-12 17:36:42 TT FIX Data: Disconnected. | 2016-12-12 17:36:42 Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2016-12-12 17:36:42 To prevent further connection attempts, select 'File >> Disconnect'. | 2016-12-12 17:36:42 AMP/TTNet | Disconnected. | 2016-12-12 17:36:42 Will reconnect to the server in 3.0 seconds. Select 'File >> Disconnect' to prevent further connection attempts. | 2016-12-12 17:36:42 AMP/TTNet | Connecting. | 2016-12-12 17:36:45 TT FIX Data | Connecting to 12.41.48.53. Port 10501 | 2016-12-12 17:36:45 TT FIX Data socket (11) | Connected. | 2016-12-12 17:36:45 TT FIX Data: Sending the Logon message. | 2016-12-12 17:36:45 TT FIX Data: Received a FIX message missing required field TargetCompID <56>. | 2016-12-12 17:36:45 * FIX Message: 8=FIX.4.29=0021135=549=TT_PRICE34=152=20161212-17:36:45.17058=Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator.18000=110=186 | 2016-12-12 17:36:45 * TT FIX Data: Received a Logout message. Text = Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator. | 2016-12-12 17:36:45 TT FIX Data: Sending a Logout message. Text = Received Logout message. | 2016-12-12 17:36:45 TT FIX Data socket (11) | Shutdown and closed. | 2016-12-12 17:36:45 TT FIX Data: Disconnected. | 2016-12-12 17:36:45 Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2016-12-12 17:36:45 To prevent further connection attempts, select 'File >> Disconnect'. | 2016-12-12 17:36:45 AMP/TTNet | Disconnected. | 2016-12-12 17:36:45 Will reconnect to the server in 3.0 seconds. Select 'File >> Disconnect' to prevent further connection attempts. | 2016-12-12 17:36:45 AMP/TTNet | Connecting. | 2016-12-12 17:36:48 TT FIX Data | Connecting to 12.41.48.53. Port 10501 | 2016-12-12 17:36:48 TT FIX Data socket (12) | Connected. | 2016-12-12 17:36:48 TT FIX Data: Sending the Logon message. | 2016-12-12 17:36:48 TT FIX Data: Received a FIX message missing required field TargetCompID <56>. | 2016-12-12 17:36:48 * FIX Message: 8=FIX.4.29=0021135=549=TT_PRICE34=152=20161212-17:36:48.55458=Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator.18000=110=195 | 2016-12-12 17:36:48 * TT FIX Data: Received a Logout message. Text = Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator. | 2016-12-12 17:36:48 TT FIX Data: Sending a Logout message. Text = Received Logout message. | 2016-12-12 17:36:48 TT FIX Data socket (12) | Shutdown and closed. | 2016-12-12 17:36:48 TT FIX Data: Disconnected. | 2016-12-12 17:36:48 Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2016-12-12 17:36:48 To prevent further connection attempts, select 'File >> Disconnect'. | 2016-12-12 17:36:48 AMP/TTNet | Disconnected. | 2016-12-12 17:36:48 Will reconnect to the server in 3.0 seconds. Select 'File >> Disconnect' to prevent further connection attempts. | 2016-12-12 17:36:48 AMP/TTNet | Connecting. | 2016-12-12 17:36:51 TT FIX Data | Connecting to 12.41.48.53. Port 10501 | 2016-12-12 17:36:51 TT FIX Data socket (13) | Connected. | 2016-12-12 17:36:52 TT FIX Data: Sending the Logon message. | 2016-12-12 17:36:52 TT FIX Data: Received a FIX message missing required field TargetCompID <56>. | 2016-12-12 17:36:52 * FIX Message: 8=FIX.4.29=0021135=549=TT_PRICE34=152=20161212-17:36:51.92058=Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator.18000=110=186 | 2016-12-12 17:36:52 * TT FIX Data: Received a Logout message. Text = Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator. | 2016-12-12 17:36:52 TT FIX Data: Sending a Logout message. Text = Received Logout message. | 2016-12-12 17:36:52 TT FIX Data socket (13) | Shutdown and closed. | 2016-12-12 17:36:52 TT FIX Data: Disconnected. | 2016-12-12 17:36:52 Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2016-12-12 17:36:52 To prevent further connection attempts, select 'File >> Disconnect'. | 2016-12-12 17:36:52 AMP/TTNet | Disconnected. | 2016-12-12 17:36:52 Will reconnect to the server in 3.0 seconds. Select 'File >> Disconnect' to prevent further connection attempts. | 2016-12-12 17:36:52 AMP/TTNet | Connecting. | 2016-12-12 17:36:55 TT FIX Data | Connecting to 12.41.48.53. Port 10501 | 2016-12-12 17:36:55 TT FIX Data socket (14) | Connected. | 2016-12-12 17:36:55 TT FIX Data: Sending the Logon message. | 2016-12-12 17:36:55 TT FIX Data: Received a FIX message missing required field TargetCompID <56>. | 2016-12-12 17:36:55 * FIX Message: 8=FIX.4.29=0021135=549=TT_PRICE34=152=20161212-17:36:55.30058=Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator.18000=110=182 | 2016-12-12 17:36:55 * TT FIX Data: Received a Logout message. Text = Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator. | 2016-12-12 17:36:55 TT FIX Data: Sending a Logout message. Text = Received Logout message. | 2016-12-12 17:36:55 TT FIX Data socket (14) | Shutdown and closed. | 2016-12-12 17:36:55 TT FIX Data: Disconnected. | 2016-12-12 17:36:55 Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2016-12-12 17:36:55 To prevent further connection attempts, select 'File >> Disconnect'. | 2016-12-12 17:36:55 AMP/TTNet | Disconnected. | 2016-12-12 17:36:55 Will reconnect to the server in 3.0 seconds. Select 'File >> Disconnect' to prevent further connection attempts. | 2016-12-12 17:36:55 AMP/TTNet | Connecting. | 2016-12-12 17:36:58 TT FIX Data | Connecting to 12.41.48.53. Port 10501 | 2016-12-12 17:36:58 TT FIX Data socket (15) | Connected. | 2016-12-12 17:36:58 TT FIX Data: Sending the Logon message. | 2016-12-12 17:36:58 TT FIX Data: Received a FIX message missing required field TargetCompID <56>. | 2016-12-12 17:36:59 * FIX Message: 8=FIX.4.29=0021135=549=TT_PRICE34=152=20161212-17:36:58.70358=Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator.18000=110=192 | 2016-12-12 17:36:59 * TT FIX Data: Received a Logout message. Text = Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator. | 2016-12-12 17:36:59 TT FIX Data: Sending a Logout message. Text = Received Logout message. | 2016-12-12 17:36:59 TT FIX Data socket (15) | Shutdown and closed. | 2016-12-12 17:36:59 TT FIX Data: Disconnected. | 2016-12-12 17:36:59 Error connecting to Data or Trading service. For help with this issue, press the 'Send For Analysis' button on this window. | 2016-12-12 17:36:59 To prevent further connection attempts, select 'File >> Disconnect'. | 2016-12-12 17:36:59 AMP/TTNet | Disconnected. | 2016-12-12 17:36:59 Will reconnect to the server in 3.0 seconds. Select 'File >> Disconnect' to prevent further connection attempts. | 2016-12-12 17:36:59 AMP/TTNet | Connecting. | 2016-12-12 17:37:02 TT FIX Data | Connecting to 12.41.48.53. Port 10501 | 2016-12-12 17:37:02 TT FIX Data socket (16) | Connected. | 2016-12-12 17:37:02 TT FIX Data: Sending the Logon message. | 2016-12-12 17:37:02 File >> Disconnect selected. | 2016-12-12 17:37:02 TT FIX Data: DisconnectFIX called. | 2016-12-12 17:37:02 TT FIX Data: Sending a Logout message. | 2016-12-12 17:37:02 AMP/TTNet | Disconnected. | 2016-12-12 17:37:02 TT FIX Data: Received a FIX message missing required field TargetCompID <56>. | 2016-12-12 17:37:02 * FIX Message: 8=FIX.4.29=0021135=549=TT_PRICE34=152=20161212-17:37:02.09258=Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator.18000=110=183 | 2016-12-12 17:37:02 * TT FIX Data: Received a Logout message. Text = Unable to login to FIX Adapter AMPNON1ORPR: TTUserSetup Error - is not authorized to use FIX Adapter. Please contact your TT User Setup Administrator. | 2016-12-12 17:37:02 TT FIX Data socket (16) | Shutdown and closed. | 2016-12-12 17:37:02 TT FIX Data: Disconnected. | 2016-12-12 17:37:02 |
[2016-12-12 18:06:12] |
Sierra Chart Engineering - Posts: 104368 |
This is now resolved for your account. It will no longer switch back to AMP/TTNet .
Sierra Chart Support - Engineering Level Your definitive source for support. Other responses are from users. Try to keep your questions brief and to the point. Be aware of support policy: https://www.sierrachart.com/index.php?l=PostingInformation.php#GeneralInformation For the most reliable, advanced, and zero cost futures order routing, *change* to the Teton service: Sierra Chart Teton Futures Order Routing |