Home >> (Table of Contents) Studies and Indicators >> Technical Studies Reference >> Study Subgraph Reverse Order
Technical Studies Reference
- Technical Studies Reference
- Common Study Inputs (Opens a new page)
- Using Studies (Opens a new page)
Study Subgraph Reverse Order
This study reverses the order of all values of the data specified by the Input Data Input.
Let \(X_t\) denote the value of the Input Data at Index \(t\), and let \(N\) denote the value of sc.ArraySize, which is the number of bars in the chart. Then the value of Study Subgraph Reverse Order at Index \(t\) is equal to \(X_{N - t}\).
If the Draw Zeros Input is set to Yes, then all values of \(X_{N - t}\) are displayed. If this Input is set to No, then only the nonzero values are displayed.
Inputs
- Input Data
- Draw Zeros: Determines whether zero values of the reversed Input Data are to be drawn.
Spreadsheet
The spreadsheet below contains the formulas for this study in Spreadsheet format. Save this Spreadsheet to the Data Files Folder.
Open it through File >> Open Spreadsheet.
*Last modified Monday, 03rd October, 2022.